Data KAT7 S-FTP HFFR dual orange inst., 2x(4x2xawg23) 500m tromle
2x 4x2xAWG23 S-FTP CAT 7 1200 MHz LSOH Installation cable. Suitable for building structured cabling in the secondary and tertiary area. For installation of cable lines of class F, 1000 MHz. Conforming to ISO/IEC 11801, DIN EN 50173, DIN EN 50288-4-1
- Physical description
- Basic conductor: Solid AWG 23/1; bare annealed copper 0.57mm nom
- Insulation: SFS-PO
- Total number of insulated conductors: 2x8, twisted in 2x4 pairs
- Color code: Blue x White, Orange x White, Green x White, Brown x White
- Individual pair shield: Aluminium foil, providing 100% coverage, foil face out
- Overall shield: Tin-coated copper wire braid, 35% nom. coverage
- Outer jacket: Low-smoke, zero-halogen, flame retardant, non corrosive compound for indoor use
- Outer jacket thickness: 0.6mm nom.
- Color: Orange (RAL 2000)
- Overall diameter: 16x7.5mm nom.
- Mechanical properties:
- Bend radius: Dynamic: 8xD mm min., static: 4xD mm min.
- Storage temperature: -20°C - +75°C
- Temperature installation range: 0°C to +50°C
- Temperature operating range: -20°C to +60°C
- Flame tests: IEC 60332-1 (fire), IEC 60754 (gas), IEC 61034 (smoke)
- Pulling force: 150N max
- Caloric value: 650 KJ/m
- Total weight: 136 Kg/Km nom.
- Electrical properties @ 20°C
- Mean impedance: 100±5 Ohm @ 1-600 MHz
- Vp: 57-77% nom.
- Capacitance. 40 pF/m nom. @ 1 KHz
- Capacitance unbalance to ground: 1.6 pF/m nom. @ 1 KHz
- Capacitance unbalance to ground: 1.6 pF/m nom. @ 1KHz
- Insulation resistance: 0.5G Ohm/km min.
- DC resistance: 72 Ohm/Km max. (2% max. resistance unbalance)
- DC loop resistance: 147 Ohm/Km max. (2% max. resistance unbalance)
- Voltage resistance: 72Vdc max.
- Coupling attenuation: 85dB min. @ 30-100 MHz, 82-20Log(f/100)dB min. @ 100-1000 MHz
- PS-ANEXT loss: 92.5-15Log(f) dB min. @ 1-600 MHz (67 dB max.)
- PS-AACRF: 78.2-20Log(f) dB min. @ 1-600 MHz (67 dB max.)
- Phase delay: 534+36/1/2 nS/100m max. @ f=1-1000 MHz
- Delay skew: 25 nS/100m max.
Fremhævede specifikationer
Kabeltype |
Installation |
Kategori |
KAT7 |
Længde |
500 m |
Oplægning |
Tromle |
Shielding Class |
S-FTP |
Yderligere specifikationer
Kabellængde | 500 m |
Standard for kabler | Cat7 |
Forbindelse 1 | N |
Forbindelse 2 | N |
Kabelafskærmning | SF/UTP (S-FTP) |
Farve på produkt | Orange |
Indgangs-impedans | 100 ohm (Ω) |
Materiale for kapper | Low smoke zero halogen (LSZH) |
Leder-type | Solid |
AWG ledningsstørrelse | 23/1 |
Frekvens | 1000 Mhz |
Driftstemperatur (T-T) | -20 - 60 °C |
Lagrings-temperatur (T-T) | -20 - 75 °C |
Kategoribeskrivelse:Betegnelser for skærmning:
F/UTP: Folieskærm under kappen, lederpar uskærmet
S/FTP: Skærmet under kappen, lederpar folieskærmet (også kendt som PiMF)
SF/UTP: Skærmet og folieskærmet under kappen, lederpar uskærmet
U/FTP: Uskærmet under kappen, lederpar folieskærmet (også kendt som PiMF)
UTP: Uskærmet under kappen, lederpar uskærmet (også kendt som U/UTP)
Kategorier (Standard specifikationer):
KAT5E: 100MHz båndbredde, 10/100/1000 Mbit (1000Base-T) - Maks. rækkevidde på 55 meter
KAT6: 250MHz båndbreddde, 10 Gbit (1000Base-T) - Maks. rækkevidde på 55 meter (33 meter ved high crosstalk)
KAT6A: 500MHz båndbredde, 10 Gbit (10Gbase-T) - Maks. rækkevidde på 100 meter
KAT7: 600MHz båndbredde, 10 Gbit (Standarden er ikke vedtaget af ANSI/TIA, hvorfor der ikke kan gives specifikationer)
KAT7A: 1000MHz båndbredde, 10 Gbit (Standarden er ikke vedtaget af ANSI/TIA, hvorfor der ikke kan gives specifikationer)
KAT8.1: 2000MHz båndbredde, 40 Gbit (25G/40GBase-T) - Maks. rækkevidde 30 meter, skal benytte skærmede konnektorer
PoE (Power over Ethernet):
Som udgangspunkt kan alle ethernet kabler fra KAT5E og op benyttes til PoE, dog skal man være opmærksom på ledernes tykkelse.
Bemærk: denne beskrivelse dækker ikke nødvendigvis over specifikationer eller ydeevne for det viste produkt.